Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Ensure plug has been refitted to water pressure switch
(take care as plug can be fitted incorrectly)
Disconnect CN102 from the control PCB
(take care as plug can be fitted incorrectly)
Disconnect CN102 from the control PCB
Measurement:
Measure the resistance between pins 1 and 2 at the disconnected plug.
Resistance should be short circuit (zero resistance).
Resistance should be short circuit (zero resistance).

Isolate as per TOPs P4
and refit as necessary