Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Remove the fan, there is no need to take the venturi
off the fan

Observation:

Inspect the intake venturi for burrs or roughness.
It should be smooth without any roughness or burrs.
Burrs and others restrictions can cause a whistling noise on low rate.
Note:
1. Before reassembly check the integrity of all disturbed gaskets and seals and replace as necessary.
2. Upon reassembly all disturbed joints should be checked for gas tightness.