Set Appliance State:
Mains Power Off
CH Demand
Selector Switch to Hot Water and Heating
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Allow fan to run.
Measure voltage between Black (6) on connector X401 and Earth.
Expect approximately 6VDC
Is the voltage as expected?
Measure voltage between Black (6) on connector X401 and Earth.
Expect approximately 6VDC
Is the voltage as expected?

Isolate as per TOPs P4
and refit as necessary