Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the flame ignition harness from the spark generator
Measurement:
Test 1:
Measure the resistance the two spade connections on the ignitor
Expected resistance approx. 3.2 MOhms
Test 2:
Measure the resistance between the first spade and Earth
Expected resistance 1 MOhm or greater.
Test 3:
Measure the resistance between the second spade and Earth
Expected resistance 1 MOhm or greater.
Measure the resistance the two spade connections on the ignitor
Expected resistance approx. 3.2 MOhms
Test 2:
Measure the resistance between the first spade and Earth
Expected resistance 1 MOhm or greater.
Test 3:
Measure the resistance between the second spade and Earth
Expected resistance 1 MOhm or greater.

Isolate as per TOPs P4
and refit as necessary