Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between the top pin (blue wire)
and bottom pin (red wire) on connector CN4
Expected voltage should be greater than 7 Vac.
and bottom pin (red wire) on connector CN4
Expected voltage should be greater than 7 Vac.

Isolate as per TOPs P4
and refit as necessary