Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
CH Demand
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

With the plug in-situ measure voltage at the between the bottom two wires (pins 9 and 18) at X20 connector.
Between approximately 12 and 24 volts DC should be measured.
Notes:
1. The appliance will try to ignite 5 times before going
to lockout and the voltage will only be present
when the appliance is attempting ignition.
2. If the boiler is in lockout it will need to be reset.
3. Colour of wires may change but test points remain the same.