Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Ease connector J1 slightly off PCB to expose the silver strip to
allow for testing with probes
allow for testing with probes
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between the Grey (2) and the White (3) on connector J1
on the main PCB Connector.
The voltage will vary according to system pressure.
approx. voltage should be between 1.7 -1.9 volts DC
Note: Connector is shown disconnected for illustration purposes only.
Test should be carried out with connector on PCB.
on the main PCB Connector.
The voltage will vary according to system pressure.
approx. voltage should be between 1.7 -1.9 volts DC
| System pressure | Voltage DC | 0 bar | 1.2 |
| 1 bar | 1.7 |
| 2 bar | 2.2 |
| 3 bar | 2.8 |
Test should be carried out with connector on PCB.

Isolate as per TOPs P4
and refit as necessary