Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Mains Reset Switch OFF
Gain access to PCB (use insulation mat as necessary)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Mains reset switch on.
Measure the voltages on the test pins below the J13 connector on the main PCB.
The Voltages should conform approximately to the table below:
Black Probe PositionRed Probe PositionExpected DC Voltage
EarthPin 45
EarthPin 612 - 17 (see note)