Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove rear control panel cover to expose main PCB
Measurement:
Remove connector H2 from main PCB.
Test 1:
Measure resistance across the brown lead and blue lead connection (1 and 4) on the connector marked H2 on the main PCB.
Test 2:
Measure resistance across the live and suitable Earth.
Expected resistance O.L or greater than 1MOhm on both tests.
Test 1:
Measure resistance across the brown lead and blue lead connection (1 and 4) on the connector marked H2 on the main PCB.
Test 2:
Measure resistance across the live and suitable Earth.
Expected resistance O.L or greater than 1MOhm on both tests.

Isolate as per TOPs P4
and refit as necessary