Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the connector plug from the gas valve
Measurement:
Test 1:
Measure the resistance across terminal marked EV1 (L/H side) and terminal marked COM (centre bottom).
Resistance should be approximately 870 ohms.
Test 2:
Measure the resistance across terminal marked EV2 (R/H side) and terminal marked COM (centre bottom).
Resistance should be approximately 870 ohms.
Test 3:
Measure the resistance across terminal marked COM (centre bottom) and gas valve earth (centre top).
Resistance should be greater than 1M Ohm.
Measure the resistance across terminal marked EV1 (L/H side) and terminal marked COM (centre bottom).
Resistance should be approximately 870 ohms.
Test 2:
Measure the resistance across terminal marked EV2 (R/H side) and terminal marked COM (centre bottom).
Resistance should be approximately 870 ohms.
Test 3:
Measure the resistance across terminal marked COM (centre bottom) and gas valve earth (centre top).
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary