Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X18 from the PCB
Disconnect the electrical connection from the pump (main supply)
With the aid of a screwdriver carefully remove the cover (as below)
Disconnect the electrical connection from the pump (main supply)
With the aid of a screwdriver carefully remove the cover (as below)
Measurement:
Measure the resistance between each of the wires
on the pump main supply harness.
Brown to brown
Blue to blue
Earth to earth
Expect continuity / zero resistance on each wire.
Also visually inspect the condition of the harness.
Note:
Ensure a good connection is made or misdiagnosis may occur.
on the pump main supply harness.
Brown to brown
Blue to blue
Earth to earth
Expect continuity / zero resistance on each wire.
Also visually inspect the condition of the harness.
Note:
Ensure a good connection is made or misdiagnosis may occur.

Isolate as per TOPs P4
and refit as necessary