Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the display harness connector from the main PCB
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between each of the points on the main PCB listed below to a suitable earth.
Numbers quoted are counting downwards from the top wire on the display harness connector.
The Voltages should conform approximately to the table below:
Numbers quoted are counting downwards from the top wire on the display harness connector.
The Voltages should conform approximately to the table below:
| Test point | DC Volts | 1 | 0 |
| 2 | 4.7 |
| 3 | 21.8 |
| 4 | 5 |
| 5 | 24 |
| 6 | 5 |

Isolate as per TOPs P4
and refit as necessary