Set Appliance State:
Mains Power Off
NO Demands
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset the appliance. (Press reset button once then release)
Allow the appliance to complete its 2 minute self check program.
At the end of the self check program the boiler should be at rest
without the fan or pump running.
Note:
1. It is important to wait the full two minutes for the self check program to complete properly even if the boiler appears to have finished within 2 minutes.
2. If the spanner symbol and fault code appear together on the display, you MUST choose the 'FAULT CODE SHOWN' option from below, failure to do so will result in misdiagnosis.
Allow the appliance to complete its 2 minute self check program.
At the end of the self check program the boiler should be at rest
without the fan or pump running.
Note:
1. It is important to wait the full two minutes for the self check program to complete properly even if the boiler appears to have finished within 2 minutes.
2. If the spanner symbol and fault code appear together on the display, you MUST choose the 'FAULT CODE SHOWN' option from below, failure to do so will result in misdiagnosis.