Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector X25 from the PCB
Measurement:
Test 1:
Measure the resistance between pin 7 (Blue & Black)
and pin 8 (Red) on connector X25.
Expect approximately 117 ohms.
Test 2:
Measure the resistance between pin 7 (Blue & Black)
and a suitable earth
Expected resistance greater than 1 MOhm.
Test 3:
Measure the resistance between pin 8 (Red) and
and a suitable earth
Expected resistance greater than 1 MOhm.
Measure the resistance between pin 7 (Blue & Black)
and pin 8 (Red) on connector X25.
Expect approximately 117 ohms.
Test 2:
Measure the resistance between pin 7 (Blue & Black)
and a suitable earth
Expected resistance greater than 1 MOhm.
Test 3:
Measure the resistance between pin 8 (Red) and
and a suitable earth
Expected resistance greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary