Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
CH Demand
Gain access to PCB (use Insulation Mat as required)
Remove 4 wire fan connector from fan and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the DC voltage between pin 4 (grey) on connector X20 and a suitable earth.
Expect a reading of approximately 22 Vdc.
Note:
Each pin on the PCB connector is numbered.