Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Both Temperature Dials up to Max
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Measure the voltage between an earth connection and each of the pins listed in the table below at connector X50, with pin 1 being the top left.
(Use the electrical insulation mat as necessary whilst carrying out this test).
The voltages should conform approximately to the table below:
Approx. Voltages
Pin 1 = 5vdcPin 5 = 5vdc
Pin 2 = 5vdc Pin 6 = 0vdc
Pin 3 = 0vdcPin 7 = 5vdc
Pin 4 = 5vdcPin 8 = 23vdc