Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
CH Demand
Gain access to PCB (use Insulation Mat as required)
Disconnect the fan connector from the
fan assembly (place in a safe position)
On-Off switch on
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the dc voltage between connector X20 on PCB connection 17(red) and a suitable earth.
Expected voltage approx. 24vdc.