Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
CH Demand
Attach pressure gauge to gas valve inlet pressure test point
On-Off switch on
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Allow fan to run.
Monitor the U gauge - the inlet pressure should remain satisfactory throughout the ignition cycle and a dip should be seen during the sparking stage indicating the gas valve is opening.
Notes:
1. Lockout may occur after 5 attempts to ignite. If lockout occurs or the boiler is already in lockout then the reset will have to be depressed.
2. When "U" gauge is removed test point should be tightened and checked for gas tightness.