Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect X20 from PCB
Measurement:
Test 1:
Measure resistance across connections 9 (blue) and 18 (red) of disconnected connector X20.
Expected resistance of approx 52 ohms.
Test 2:
Measure resistance across connection 9 (blue) of disconnected connector X20 to a suitable earth point.
Expected resistance should be greater than 1 Mohm.
Measure resistance across connections 9 (blue) and 18 (red) of disconnected connector X20.
Expected resistance of approx 52 ohms.
Test 2:
Measure resistance across connection 9 (blue) of disconnected connector X20 to a suitable earth point.
Expected resistance should be greater than 1 Mohm.

Isolate as per TOPs P4
and refit as necessary