Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
ON/OFF switch ON
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for dc voltage across connections 11 (red) and 1 (black) at
connector X2 on the PCB.
Expected voltage 5vdc.
connector X2 on the PCB.
Expected voltage 5vdc.

Isolate as per TOPs P4