Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X20 from the PCB
Measurement:
Measure the resistance across connection 16 (blue) and connections 4 (grey) and 3 (black) of the disconnected connector X20.
Note:
Black meter probe is connected to connection 16 (blue) for both of these resistance tests.
Expected resistances should be as table below.
Note:
Black meter probe is connected to connection 16 (blue) for both of these resistance tests.
Expected resistances should be as table below.
| Connection | Resistance (approx) |
| Test 1 / 16 - 4 | 22.7 kohms |
| Test 2 / 16 - 3 | 1 Mohm or greater |

Isolate as per TOPs P4
and refit as necessary