Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB
Use insulation mat as required
Use insulation mat as required
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
With the fan running measure the DC voltage between the yellow wire (pin 5) at connector J4 on the PCB and a suitable earth point.
Expect approx. 12V DC.
Expect approx. 12V DC.

Isolate as per TOPs P4
and refit as necessary