Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Main On/Off Control in the On position
CH Temperature Control to Maximum
Remove side cover from Pump
Remove Yellow plug X12 from Motherboard and make safe
CH Temperature Control to Maximum
Remove side cover from Pump
Remove Yellow plug X12 from Motherboard and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
If a fault code is displayed press boiler 'Reset' button.
Measure Mains Voltage across L and N of Pump.
Measure Mains Voltage across L and N of Pump.

Isolate as per TOPs P4
and refit as necessary