Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Main On/Off Control in the On position
CH Temperature Control to Maximum
Remove Yellow connector X12 from Motherboard and make safe
CH Temperature Control to Maximum
Remove Yellow connector X12 from Motherboard and make safe
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
If a fault code is displayed press boiler 'Reset' button.
Measure DC Voltage on across X12 on Motherboard.
This should lie between 20.0V and 30.0V DC.
Measure DC Voltage on across X12 on Motherboard.
This should lie between 20.0V and 30.0V DC.

Isolate as per TOPs P4
and refit as necessary