Set Appliance State:
CH Demand
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance if required.
(press and hold the power button for 4 seconds then release)
Allow fan to run.
Listen to the appliance.
As the boiler goes through its ignition cycle can the burner be heard to ignite?
(burner may be heard to ignite repeatedly if flame is not establishing)
Notes:
1. Burner is located at the top of the primary heat exchanger.
2. Appliance may enter lockout during this test, reset as necessary until test is complete.
(press and hold the power button for 4 seconds then release)
Allow fan to run.
Listen to the appliance.
As the boiler goes through its ignition cycle can the burner be heard to ignite?
(burner may be heard to ignite repeatedly if flame is not establishing)
Notes:
1. Burner is located at the top of the primary heat exchanger.
2. Appliance may enter lockout during this test, reset as necessary until test is complete.