Observation:


CODE /DESCRIPTION CODE /DESCRIPTION
F00 /F10 Flow heating temperature sensor faultF61 to F67Fault in the main board
F01 / F11Return heating temperature sensor faultF68Fluctuation of flame signal
F20Overheating faultF70User interface incompatible with main PCB
F22Water pressure of the installation (<0.3 bar) F71Flow heating temperature sensor fault
F23Max temp difference reached return & flow heatingF72Permanent temp difference flow & return sensors
F24Water circulation fault F73 / F74Heating circuit pressure sensor fault
F26Fault gas valve motor F76Thermal fuse fault
F27Flame detection fault F77Fault in gas valve motor
F28Ignition fault F83No water in system, temp does not increase
F29Loss of flame during operation F84Permanent temp difference between sensors
F32Incorrect air pressure F85Flow and return heating sensors fault
F49Ebus voltage fault F86Under floor heating contact fault
ErrUser interface fault RESETFault