INTERFACE HARNESS CONTINUITY
Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance
Remove the harness from the interface PCB and X51 at the PCB
Measurement:
Measure the continuity, in turn, of the wires between the each end of the harness.
CONTINUITY / ZERO RESISTANCE MEASURED AT EACH WIRE IN THE HARNESS
OPEN CIRCUIT MEASURED ACROSS 1 OR MORE OF THE HARNESS WIRES
After test don't forget
Isolate as per TOPs P4
and refit as necessary
Isolate as per TOPs P4
and refit as necessary