Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Remove both leads from the outlet side of the spark generator.
Place the earth lead of the spark generator output close to the
spark lead terminal of the generator
Place the earth lead of the spark generator output close to the
spark lead terminal of the generator
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Important keep clear of the lead and generator during this test!
During the ignition sequence observe the earth lead/ generator terminal.
Is sparking seen?
Once this test is completed ISOLATE MAINS POWER and reconnect the spark and earth leads to the generator.
During the ignition sequence observe the earth lead/ generator terminal.
Is sparking seen?
Once this test is completed ISOLATE MAINS POWER and reconnect the spark and earth leads to the generator.
Isolate as per TOPs P4
and refit as necessary