Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
CH Demand
Gain access to PCB (use Insulation Mat as required)
Ensure the meter is set to full range mode.
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset any lockout conditions and allow the ignition sequence to commence.
Measure voltage across Pin-4 (Brown) and Pin-1 (Blue) of connector X2 (top right corner of PCB).
At rest there should be approx. 30Vdc at the connections which should rise to approx. 60Vdc while sparking.
NOTE:
Sparking should commence at the same time as the fan starts and will last approx. 5seconds then stop for 5seconds, this will repeat 5 times.