Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the connector from the gas valve
Measurement:
Test 1:
Measure the resistance from pin 1 to 4 of the gas valve solenoid.
Expect a resistance of approximately 58 ohms.
Test 2:
Measure the resistance between pin 1 and a suitable earth.
Expect a resistance of 1Mohm or greater.
Are the resistances measured as expected?
Measure the resistance from pin 1 to 4 of the gas valve solenoid.
Expect a resistance of approximately 58 ohms.
Test 2:
Measure the resistance between pin 1 and a suitable earth.
Expect a resistance of 1Mohm or greater.
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary