Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect X20 from the PCB
Disconnect the connector from the Fan

Measurement:

Measure the resistance of each wire in the Harness to the fan, the connections are as follows:
WirePosition in X20
Red19
White3
Yellow4
Blue20