Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Gain access to PCB (use insulation mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Measure the voltage on the left hand terminal block between the connections marked "SL2 IN" and "N".
With no demand mains voltage should be present.
Note:
Voltage on SL2 is supplied by the HW OFF
at the cylinder thermostat / timer.