Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove connector from spark generator
Pull X1 and X2 back slightly to expose test pins

Measurement:

Check for continuity (zero resistance) of the blue and brown wires running from the disconnected plug to X2/X1 on the PCB.
Brown = X2 Pin 4.
Blue = X1 Pin 2.
Inspect harness and connectors for good overall condition.
Note:
Wires may be multicoloured.