Set Appliance State:
Mains Power Off
CH Demand
Temperature control set to MAX
Ensure boiler is cool
Selector switch set to OFF
Ensure boiler is cool
Selector switch set to OFF
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Ensure the start-up sequence has completed and the boiler is showing 0.
Fan must still be running for initial purge period (within 4 minutes of power on).
Turn selector switch to ON.
Display should change to "c", the pump should run and the fan should pause
for approximately 2 seconds and then start running again.
Does the boiler react as described above?
Fan must still be running for initial purge period (within 4 minutes of power on).
Turn selector switch to ON.
Display should change to "c", the pump should run and the fan should pause
for approximately 2 seconds and then start running again.
Does the boiler react as described above?