Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove ribbon connector at bottom of PCB
Unclip and flip the PCB onto its back
Unclip and flip the PCB onto its back
Measurement:
Measure resistance across the integral fuse on the PCB using the pins shown in the image.
Short circuit (zero Ohms) expected.
Note:
The fuse may differ in appearance but the pins will remain in the same location.
Short circuit (zero Ohms) expected.
Note:
The fuse may differ in appearance but the pins will remain in the same location.

Isolate as per TOPs P4
and refit as necessary