Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Disconnect the ribbon cable marked X10 at bottom of PCB
Disconnect the ribbon cable marked X10 at bottom of PCB
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage on the 3rd pin
from the left to a suitable earth point.
Voltage should be approximately 5V DC.
from the left to a suitable earth point.
Voltage should be approximately 5V DC.

Isolate as per TOPs P4
and refit as necessary