Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Gain access to PCB (use insulation mat as required)
Pull connector X1 back slightly to expose test points
Pull connector X1 back slightly to expose test points
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the AC volts between pin 5 (brown)
and pin 6 (blue) at connector X1 on the PCB.
Mains voltage should be present.
and pin 6 (blue) at connector X1 on the PCB.
Mains voltage should be present.

Isolate as per TOPs P4
and refit as necessary