Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use insulation mat as required)
Pull connector X1 back slightly to expose test points
Pull connector X1 back slightly to expose test points
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the AC volts between pin 1 (brown)
and pin 2 (blue) at connector X1C on the PCB.
Mains voltage should be present.
Note:
Voltage will only be present for 30 seconds after power is turned on, repeat as necessary until test complete
and pin 2 (blue) at connector X1C on the PCB.
Mains voltage should be present.
Note:
Voltage will only be present for 30 seconds after power is turned on, repeat as necessary until test complete

Isolate as per TOPs P4
and refit as necessary